4.2
System Programming
Assigns the call barring class for System Speed Dialling numbers. System Speed Dialling
numbers can be assigned in program [001] “System Speed Dialling Entry”.
* Boundary Class: 1 through 5
Default
Boundary Class -1
• Feature Reference
Section 3, Features
Call Barring for System Speed Dialling
1
0
3
[301] Call Barring – System Speed Dialling Boundary Class
☞
NEXT
STORE
END
(Class-1···5)*
SELECT
Assigns up to 20 carrier excepted codes, for example, Per Call Block code (
141). The
system disregards the assigned code, and call barring and ARS are applied to the numbers
after the code.
Example:
Code no. 01:
141
Dialling number:
141 01633 877 467
disregarded
applied to the call barring and ARS
Default
All codes – Not stored.
• “x” (press the PAUSE button) substitutes any number (= wild card).
• To correct a wrong entry, press the CLEAR button and enter the new one.
0
0
3
[300] Carrier Excepted Code Assignment
NEXT
END
code
(01···20)
code no.
!
!
10 digits max.
(0···9, ,#)
SELECT
To continue
NEXT
PREV
or
To continue
STORE
PSQX1708ZA-08E.QX 99.10.15 1:01 PM Page 32
Summary of Contents for KX-TA624
Page 15: ...Section 1 Basic System Construction ...
Page 17: ...Section 2 Installation ...
Page 51: ...Section 3 Features ...
Page 125: ...Section 4 System Programming ...
Page 212: ...4 88 System Programming ...
Page 213: ...Section 5 Appendix ...
Page 222: ...5 10 Appendix ...
Page 223: ...Section 6 Troubleshooting ...
Page 227: ...Section 7 Programming Tables ...
Page 275: ...Section 1 Installation ...
Page 287: ...Section 2 Operations ...
Page 306: ...10 ...
Page 409: ...Appendix Section 2 Appendix ...
Page 420: ...2 12 Appendix ...
Page 426: ...Memo ...
Page 427: ......