Station Features and Operation (PT/SLT)
244
User Manual
Checking the time setting
Conditions
•
The system clock must be set correctly beforehand.
•
There is no limit to the number of the extensions who can set the Timed Reminder at the
same time.
•
Only the latest time setting is valid at the extension whether it was set by the extension user
(Timed Reminder) or by the Manager extension or an Operator (Timed Reminder, Remote).
•
Station Message Detail Recording (SMDR)
SMDR automatically records the detailed Timed Reminder information (date, time,
extension number, start/no answer). It is programmable to be printed out when the Timed
Reminder starts and the alarm is not answered. Refer to "Station Message Detail Recording
(SMDR)" in the Features Guide for further information.
Programming Guide References
[000] Date and Time Set
[217] Timed Reminder Alarm Ring Time
[990] System Additional Information
User Manual References
4.3.78
Timed Reminder
Display PT
Lift the handset or press
SP-PHONE.
Dial the desired extension
number or press DSS on
which you have set
the Timed Reminder.
Hang up or press
SP-PHONE.
extension no.
Dial 7 2.
or
7
2
<PT Display Example>
If "10:10" has been set, the display shows;
or
Alarm 10:10AM
Alarm 10:10AM
If time setting is not stored.
Alarm Not Stored
–
only one time
–
daily
(DSS)
Summary of Contents for KX-T7020
Page 2: ...2 User Manual Thank you for purchasing the Panasonic Telephone System ...
Page 12: ...Table of Contents 12 User Manual ...
Page 42: ...Station Programming 42 User Manual ...
Page 43: ...User Programming User Manual 43 Section 3 User Programming ...
Page 62: ...User Programming 62 User Manual ...
Page 258: ...DSS Console Features 258 User Manual ...
Page 259: ...Appendix User Manual 259 Section 6 Appendix ...
Page 273: ...Index 273 Section 7 Index ...
Page 277: ...Index 277 ...
Page 278: ...Index 278 ...
Page 279: ...Index 279 ...