Feature Guide References
5.2.1 IP Proprietary Telephone (IP-PT)
Keep Alive Time-Out
Specifies the length of time that the PBX will continue to consider an IP-PT to be active even if it receives no
transmissions from that IP-PT. The PBX constantly confirms the status of IP-PTs. If no communications are
received from an IP-PT for the duration specified here, the PBX considers the IP-PT to be unreachable, and
sets the port status to
Fault
.
During operation, set between 10 s and 60 s. Settings over 60 s, and
Disable
, are used for debugging purposes,
and IP-PTs cannot be guaranteed to function normally in these circumstances. Do not use debugging settings
unless instructed to do so.
To change the value displayed here, click
Common Settings
and set the desired value.
Value Range
Disable, 10–120 s
Maintenance Console Location
9.13 PBX Configuration—[1-1] Configuration—Slot—V-IPEXT—Card Property
Feature Guide References
5.2.1 IP Proprietary Telephone (IP-PT)
First Resending Time (PTAP)
Specifies the length of time that the PBX waits before starting to resend PTAP (Panasonic Telephony
Administration Protocol) data.
To change the value displayed here, click
Common Settings
and set the desired value.
Value Range
500
´
n (n=1–16) ms
Maintenance Console Location
9.13 PBX Configuration—[1-1] Configuration—Slot—V-IPEXT—Card Property
Feature Guide References
5.2.1 IP Proprietary Telephone (IP-PT)
Resending Time Out (PTAP)
Specifies the length of time after which the PBX terminates resending PTAP (Panasonic Telephony
Administration Protocol) data.
To change the value displayed here, click
Common Settings
and set the desired value.
Value Range
150–240 s
PC Programming Manual
299
9.13 PBX Configuration—[1-1] Configuration—Slot—V-IPEXT—Card Property
Summary of Contents for KX-NS500
Page 12: ...12 PC Programming Manual Table of Contents ...
Page 18: ...Table 2 For NE model 18 PC Programming Manual 1 1 3 Entering Characters ...
Page 19: ...Table 3 For RU UC model PC Programming Manual 19 1 1 3 Entering Characters ...
Page 20: ...Table 4 For Greece 20 PC Programming Manual 1 1 3 Entering Characters ...
Page 50: ...50 PC Programming Manual 2 3 Frequently Asked Questions FAQ ...
Page 56: ...56 PC Programming Manual 3 1 Home Screen ...
Page 74: ...74 PC Programming Manual 5 4 System Control System Shutdown ...
Page 142: ...142 PC Programming Manual 7 12 Utility CS Web Connection ...
Page 552: ...552 PC Programming Manual 10 11 2 PBX Configuration 2 11 2 System Audio Gain Card ...
Page 576: ...5 1 2 Group 576 PC Programming Manual 11 4 PBX Configuration 3 4 Group Paging Group ...
Page 758: ...758 PC Programming Manual 13 5 PBX Configuration 5 5 Optional Device External Sensor ...
Page 810: ...810 PC Programming Manual 17 5 PBX Configuration 9 5 Private Network Centralised UM VM Unit ...
Page 828: ...828 PC Programming Manual 18 4 PBX Configuration 10 5 CO Incoming Call Miscellaneous ...
Page 850: ...850 PC Programming Manual 19 3 PBX Configuration 11 3 Maintenance Air Synchronisation ...
Page 884: ...884 PC Programming Manual 20 1 3 UM Configuration 1 3 Mailbox Settings Auto Configuration ...
Page 976: ...976 PC Programming Manual 26 1 UM Configuration 7 System Security ...
Page 1007: ...Feature Programming References PC Programming Manual 1007 ...