1-1-26
1
1
Single-Type
1-1. Unit Specifications
Low Silhouette Ducted Type S-60PF1E5B / U-60PZ2R5
INDOOR
MODEL
S–60PF1E5B
–
–
PANEL
MODEL
–
–
–
OUTDOOR
MODEL
–
U-60PZ2R5
–
Branch pipe
MODEL
–
Performance test condition
ISO13253 / AS/NZS3823.1
Power supply
ø, Hz
1ø 50 Hz
1ø 50 Hz
V
–
230V
240V
–
230V
240V
Min
Max
C
O
O
L
I
N
G
Capacity
kW
–
6.0
6.0
–
–
–
2.0
7.1
BTU/h
–
20500
20500
–
–
–
6800
24200
Current
A
–
0.89
0.87
–
7.05
6.75
–
–
Input power
W
–
120
120
–
1.460k
1.460k
–
–
TOTAL W
–
–
1.580k
1.580k
380
2.080k
Annual consumption
TOTAL kWh *
4
–
–
790
–
–
–
EER/ AEER/ STAR RATING
TOTAL (W/W/-)
–
–
–
–
3.80/3.66/-
3.80
5.26
3.41
Power factor
%
–
–
–
–
90
90
–
–
Noise indoor
dB-A (H/M/L)
35/32/26
–
–
–
Power Level dB
58/55/49
–
–
–
Noise outdoor
dB-A (H/L)
–
46/–
–
–
Power Level dB
–
65/–
–
–
H
E
A
T
I
N
G
Capacity
kW
–
6.0
6.0
–
–
–
1.8
7.6
BTU/h
–
20500
20500
–
–
–
6100
25900
Current
A
–
0.89
0.87
–
5.85
5.60
–
–
Input power
W
–
120
120
–
1.210k
1.210k
–
–
TOTAL W
–
–
1.330k
1.330k
310
2.380k
COP/ ACOP/ STAR RATING
TOTAL (W/W/-)
–
–
–
–
4.51/4.32/-
4.51
5.81
3.19
Power factor
%
–
–
–
–
90
90
–
–
Noise indoor
dB-A (H/M/L)
35/32/26
–
–
–
Power Level dB
58/55/49
–
–
–
Noise outdoor
dB-A (H/L)
–
48/–
–
–
Power Level dB
–
66/–
–
–
EXTRA LOW TEMP Total capacity(kW) / Input power(W) / COP
–
–
Max Current (A) / Max Input power (W)
–
1.20/160
1.15/160
–
16.4/3.39k 16.4/3.54k
–
Starting current (A) / Comp output (W)
–
–
–
7.05/1.7k 6.75/1.7k
–
Network Impedance (ΩMAX.)
–
–
–
Fan motor output (Indoor/Outdoor) W
124
60
–
Moisture removal volume
L/h(Pt/h)
3.4
(7.1)
–
–
External static pressure
Pa
70 (MIN10 – MAX150)
–
–
Indoor
Air flow
Cooling
m
3
/min (ft
3
/min)
21/19/15
(742 / 671 / 530)
–
–
–
Heating
m
3
/min (ft
3
/min)
21/19/15
(742 / 671 / 530)
–
–
–
Outdoor
Air flow
Cooling
m
3
/min (ft
3
/min)
–
45
(1589)
–
–
Heating
m
3
/min (ft
3
/min)
–
45
(1589)
–
–
Refrigerant type / amount
g
(oz)
–
R32
1.45k
(51.1)
–
Product dimension
Height mm(inch)
290
(11–13/32)
695
(27-23/64)
–
Width mm(inch)
1000
(39–3/8)
875
(34-29/64)
–
Depth mm(inch)
700
(27–9/16)
320
(12-38/64)
–
Packing dimension
Height mm(inch)
355
(13-31/32)
761
(29-61/64)
–
Width mm(inch)
1214
(47-13/16)
1049
(41-19/64)
–
Depth mm(inch)
850
(33-15/32)
460
(18-7/64)
–
Weight
(NET) k
g
(lb)
33
(73)
44
(97)
–
(GROSS) k
g
(lb)
41
(91)
49
(108)
–
Layers limit (actually)
9 (10)
3 (4)
–
Operation condition
Cool (DBT)
18˚C – 32˚C
-10˚C – 43˚C
–
Heat (DBT)
16˚C – 30˚C
-15˚C – 24˚C
–
MAX WORKING PRESSURE HP/LP MPa (bar)
4.15/2.55 (41.5/25.5)
–
P
I
P
I
N
G
Pipe diameter mm (inch)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8) (Liquid)Ø9.52(3/8) (Gas)Ø15.88(5/8)
–
Connecting method, Standard length m(ft)
flared type, 5.0(16.4)
flared type, 5.0(16.4)
–
Pipe length range m (ft)
3 – 40m (9.8 – 131.2)
–
Indoor unit & Outdoor unit height difference m (ft)
15m(OD located lower)/30m(OD located higher) (49.2/98.4)
–
Add gas amount
g
/m (oz/ft)
35
g
/m (0.376)
–
Pipe length for additional gas m (ft)
30m (98.4)
–
*1 In case it is necessary to indicate the air flow volume in (l/s), the value in (m³/min.) shall be multiplied by 16.7 and rounded down the decimal point.
*2 If the EUROVENT Certified models can be operated under the "extra-low"temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230V shall be used.
*3 Network Impedance shall be applicable for EUROPE and CHINA models.
*4 The annual consumption is calculated by multiplying the input power at 230V(400V) by an average of 500 hours per year in cooling mode.
*5 EER and COP classification is at 230V(400V) only in accordance with EU directive 2002/31/EC.
SM830266-00_大洋州向けR32シングルTD&SM.indb 26
18/03/29 10:19:25
Summary of Contents for Inverter R32 Series
Page 93: ...1 10 10 1 SM830266 00_ R32 TD SM indb 10 18 03 29 10 19 58...
Page 94: ...1 10 11 1 SM830266 00_ R32 TD SM indb 11 18 03 29 10 19 58...
Page 95: ...1 10 12 1 SM830266 00_ R32 TD SM indb 12 18 03 29 10 19 59...
Page 96: ...1 10 13 1 SM830266 00_ R32 TD SM indb 13 18 03 29 10 20 00...
Page 241: ...MEMO 1 13 11 SM830266 00_ R32 TD SM indb 11 18 03 29 10 21 37...