Tips for Energy Saving
Avoid
Do not block the air intake and outlet of the unit. If either is obstructed, the unit will not work well, and may be damaged.
Do not let direct sunlight into the room. Use sunshades, blinds or curtains. If the walls and ceiling of the room are warmed by the
sun, it will take longer to cool the room.
Do
To prevent conditioned air from escaping, keep windows, doors and any other openings closed.
NOTE
Should the power fail while the unit is running
If the power supply for this unit is temporarily cut off, the unit will automatically resume operation once power is restored using the same
settings before the power was interrupted.
IMPORTANT INFORMATION REGARDING THE REFRIGERANT USED
NOTE
See “
■
Outdoor Unit” under the Section 1-11. Installation Instructions.
SERVICING
CAUTION
Any quali
fi
ed person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certi
fi
cate from
an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an
industr
y recognised assessment specifi
cation.
Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assis-
tance of other skilled personnel shall be carried out under the super
vision of the person competent in the use of fl
ammable refriger-
ants.
Servicing shall be performed only as recommended by the manufacturer.
Prior to beginning work on systems containing
fl
ammable refrigerants, safety checks are necessary to ensure that the risk of ignition
is minimised. For repair to the refrigerating system, (2) to (6) shall be completed prior to conducting work on the system.
(1) Work shall be undertaken under a controlled procedure so as to minimise the risk of a
fl
ammable gas or vapour being present while
the work is being performed.
(2) All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in
con
fi
ned spaces shall be avoided. The area around the workspace shall be sectioned off. Ensure that the conditions within the area
have been made safe by control of
fl
ammable material.
(3) The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware
of potentially toxic or
fl
ammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with all
applicable refrigerants, i.e. non-sparking, adequately sealed or intrinsically safe.
(4) If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate
fi
re extinguishing equipment
shall be available to hand. Have a dry powder or CO
2
fi
re extinguisher adjacent to the charging area.
(5) No person carrying out work in relation to a refrigeration system which involves exposing any pipe work shall use any sources of
ignition in such a manner that it may lead to the r
isk of fi
re or explosion. All possible ignition sources, including cigarette smoking,
should be kept suf
fi
ciently far away from the site of installation, repairing, removing and disposal, during which refrigerant can
possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make
sure that there are no fl
ammable hazards or ignition risks. “No Smoking” signs shall be displayed.
(6) Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work.
A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any
released refrigerant and preferably expel it externally into the atmosphere.
(7) Where electrical components are being changed, they shall be
fi
t for the purpose and to the correct speci
fi
cation. At all times the
manufacturer’s maintenance and service guidelines shall be followed. If in doubt, consult the manufacturer’s technical department
for assistance.
•
The charge size is in accordance with the room size within which the refrigerant containing parts are installed.
•
The ventilation machinery and outlets are operating adequately and are not obstructed.
•
Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected.
•
Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may
corrode refrigerant containing components, unless the components are constructed of materials which are inherently resistant to
being corroded or are suitably protected against being so corroded.
SM830266-00_大洋州向けR32シングルTD&SM.indb 80
18/03/29 10:21:01
Summary of Contents for Inverter R32 Series
Page 93: ...1 10 10 1 SM830266 00_ R32 TD SM indb 10 18 03 29 10 19 58...
Page 94: ...1 10 11 1 SM830266 00_ R32 TD SM indb 11 18 03 29 10 19 58...
Page 95: ...1 10 12 1 SM830266 00_ R32 TD SM indb 12 18 03 29 10 19 59...
Page 96: ...1 10 13 1 SM830266 00_ R32 TD SM indb 13 18 03 29 10 20 00...
Page 241: ...MEMO 1 13 11 SM830266 00_ R32 TD SM indb 11 18 03 29 10 21 37...