CHAPTER 2 INSTALLATION
2-4
2-4 Mounting the Sensor Head
Mounting the Sensor Head
• Fasten the sensor securely with M5 screws, using the 2 holes in the corners of the
sensor head. Limit tightening torque to within 1.2N·m. The depth of the holes is 10mm.
Take care of the length of screws to be used since the holes are not penetrated.
• Install the sensor head with the relative position of the object adjusted to the type
(50mm/85mm, diffused reflection/specular reflection) of equipment used, referencing
the installation dimension drawing starting, starting 2-5.
• It is possible to connect the sensor head (50mm) and another sensor head (85mm) at
the same time. The initial setting within the controller will correspond to the type of
equipment connected. When equipment of a different type is connected at the same
time, however, the upper/lower limit setting, hysteresis setting, and analog setting for
addition/subtraction operation will correspond to the type of equipment connected to
the head-1 side connector. When necessary, change setting contents.
• If the power supply is turned on with the connection changed (change in equipment
type: 50mm, 85mm, change in connection from 1-sensor head to 2-sensor head or vice
versa) from that when controller setting contents are saved, setting contents are
initialized. If the connection is incorrect, turn off the power supply to return the
connection to that when the controller setting was saved, then turn on the power supply
again, returning setting contents to that when the controller setting was saved. Note
that setting contents are not initialized when equipment is replaced with an equivalent
type or when the number of units is increased/decreased.
• Operate the sensor head within the temperature specification (sensor head: 0 to +45ºC,
controller: 0 to +50ºC, compact console: 0 to +50ºC).
• Service life of a semiconductor laser depends on ambient temperature during use. If
the sensor is used near a heat source, take cooling measures to lower ambient
temperature of the sensor head. The sensor generates heat, so mount the sensor head
on a unit having good heat radiation performance. *
* When installing 2 sensor heads in parallel at a 20mm or less interval, mount each
sensor head on an aluminum or iron plate having a 200cm
2
surface area.
Summary of Contents for HL-C1 Series
Page 7: ...3 Warning Label Laser Emission Indicator Measurement Range Indicator ...
Page 18: ...CHAPTER 1 NAMES AND FUNCTIONS OF PARTS ...
Page 25: ...CHAPTER 1 NAMES AND FUNCTIONS OF PARTS 1 7 MEMO ...
Page 26: ...CHAPTER 2 INSTALLATION ...
Page 32: ...CHAPTER 2 INSTALLATION 2 6 z Measurement of specular reflection 50mm type 85mm type ...
Page 39: ...CHAPTER 2 INSTALLATION 2 13 MEMO ...
Page 40: ...CHAPTER 3 INPUT AND OUTPUT TERMINAL BLOCKS ...
Page 49: ...CHAPTER 3 INPUT AND OUTPUT TERMINAL BLOCKS 3 9 MEMO ...
Page 50: ...CHAPTER 4 MEASUREMENT ...
Page 54: ...CHAPTER 4 MEASUREMENT 4 4 1 2 4 6 3 5 ...
Page 60: ...CHAPTER 5 FUNCTION ITEMS ...
Page 109: ...CHAPTER 5 FUNCTION ITEMS 5 49 MEMO ...
Page 110: ...CHAPTER 6 RS 232C CONTROL ...
Page 149: ...CHAPTER 6 RS 232C CONTROL 6 39 MEMO ...
Page 150: ...CHAPTER 7 INSPECTION AND MAINTENANCE ...
Page 152: ...CHAPTER 8 TROUBLESHOOTING ...
Page 156: ...CHAPTER 9 SPECIFICATIONS ...
Page 162: ...CHAPTER 10 DIMENSIONS ...
Page 164: ...CHAPTER 10 DIMENSIONS 10 2 z 85mm diffused reflection z 85mm specular reflection ...
Page 166: ...CHAPTER 10 DIMENSIONS 10 4 z 85mm diffused reflection z 85mm specular reflection ...
Page 168: ...CHAPTER 10 DIMENSIONS 10 6 10 2 Controller Unit mm 5 5 8 1 4 M3 55 104 120 74 40 Dpth 1 5 ...