Smooth Operator Configuration Note (77200)
Panasonic DBS
C o n f i d e n t i a l
P a g e 3
The above information is provided by Octel Communications Corporation as a guide.
See disclaimer on page 1
O c t e l C o m m u n i c a t i o n s
Call Queuing
5
[
9
]
Intercom Paging
5
[
9
]
Record Telephone Conversation
[
]
Notes:
1
See Sections 7.1 & 7.2
2
See Section 7.3
3
Rev 6.0 Only
4
See Section 7.5
5
See Section 7.4
4.1 DISCONNECT
TYPE
Disconnect on versions 2.1 up to version 6.0 can be set to send busy tone
on disconnect. Versions 6.0 can provided drop in loop current on
disconnect provided that you are using the correct station card. (See
section 3.0). For proper external disconnect supervision, Ground start or
Supervised Loop start CO lines are recommended.
In order for the disconnect to function, you must be using CPC-B version
5.00 software or higher, CPC-A 3.31 or higher, CPC-AII, CPC-S/M, or
CPC-EX.
5.0
CONFIGURING THE PANASONIC DBS
Before you begin programming, It is recommended that a hard copy of the
customer database be obtained to verify existing programming.
Not all administrative possibilities are shown. The scope of this document
does not include discussing all features and their interactions. Initial
Startup or Default values on the Switch are assumed.
5.1
CONFIGURING THE PANASONIC SYSTEM
PARAMETERS
Voice Mail Busy Tone:
The Panasonic DBS can be programmed to send a busy tone on disconnect.
FF1 2# 1# 21# (0-1)#
0 = Silence
1 = Busy Tone
Or:
AEC Disconnect / Drop in Loop
(version 6.0 only)
The AEC Disconnect is used to send Drop in Loop current on disconnect.
This applies to version 6.0 CPC A2 card VB43621A only.
FF3 (Smooth Operator port/extension)# 46 (0 or 1)#
0 = Disabled
1 = Enabled
Repeat this step for all Smooth Operator ports
AEC Disconnect Timing
This parameter is used to set the length of the Drop in loop.
FF1 2# 1# 35# (0 to 15)
15 = 1500
milliseconds of Drop in Loop (recommended)
SLT Onhook Flash Timer
The SLT Onhook timer is used to determine the length of a Hook Flash.
Programming PBX system