TMO2D User’s Manual
27
Chapter 4. Basic Programming
4.4.7 Set Communications?
Baud Rate: The display contains a bi-directional, industry-standard RS-232C serial port that enables users to operate
the instrument remotely with a keypad or computer that supports the RS-232C protocol. All keypad operations, and
most display operations, can be performed remotely through this port. (See page 20 for operation instructions.)
The display supports the communication rates of 9600, 4800, 2400, 1200 and 300 baud. The default setting is 9600
baud. Other parameters are fixed at 8 bits, 1 stop bit, no parity.
Note:
The 300-baud setting is provided for compatibility with older equipment; however, the use of 300 baud
greatly limits the computation speed of the TMO2D, and its use is not recommended.
The
Set Communications? submenu enables you to select both the baud rate and the update rate, when they
communicate with the TMO2D through the RS-232 port.
Note:
The baud rate can be changed using a terminal connected to the RS-232C port. However, this is not
recommended, as the TMO2D will immediately change to the new baud rate. Display and keyboard
operation will not be correct until the baud rate of the terminal is changed to match the new baud rate set in
the TMO2D.
Update Rate: This option is used to change the interval at which data goes to the serial port. The current data interval
will appear in brackets, and users can enter a new data interval.
SETUP MENU
Set Communications?
Press [YES] to enter the submenu.
SET COMMUNICATIONS
Set Baud Rate?
Press [YES] to enter the baud rate.
SELECT BAUD RATE
9600 baud?
Use the [NO] or arrow keys to scroll through the choices.
SELECT BAUD RATE
4800 baud?
SELECT BAUD RATE
2400 baud?
SELECT BAUD RATE
1200 baud?
SELECT BAUD RATE
300 baud?
Press [YES] to select the desired baud rate and exit.
SET COMMUNICATIONS
Set Baud Rate?
Press [NO] to proceed to the next submenu.
SET COMMUNICATIONS
Set Update Rate?
Press [YES] to set the update rate.
Summary of Contents for TMO2D
Page 1: ...panametrics com Process Analyzers 910 084 D August 2021 TMO2D Digital Display User s Manual...
Page 2: ......
Page 4: ...ii no content intended for this page...
Page 10: ...Chapter 1 Features and Capabilities 2 TMO2D User s Manual no content intended for this page...
Page 24: ...Chapter 2 Installation 16 TMO2D User s Manual no content intended for this page...
Page 26: ...Chapter 2 Installation TMO2D User s Manual 18...
Page 64: ...Chapter 4 Basic Programming 56 TMO2D User s Manual no content intended for this page...
Page 74: ...Chapter 6 Specifications 66 TMO2D User s Manual no content intended for this page...
Page 87: ...Appendix A Outline and Installation Drawings TMO2D User s Manual 79...
Page 89: ...Appendix B Menu Maps 81 TMO2D User s Manual no content intended for this page...
Page 94: ...Appendix B Menu Maps TMO2D Digital Display User s Manual 86 Figure 30 Factory Setup Menu...
Page 95: ...Appendix B Menu Maps TMO2D Digital Display User s Manual 87...
Page 99: ...76 TMO2D User s Manual no content intended for this page...
Page 100: ......