Palo Alto Networks
Installing the Hardware •
33
Install the Mandatory Front Slot Cards
5.
Install each of the four AMC/Drives into the four slots on the LPC. Figure 17 shows how an AMC/
Drive is installed. Ensure that the handle on the front of each AMC/Drive is pulled outward to the
unlocked position before sliding it into the LPC. After an AMC/drive is installed in a slot, push the
front handle in to lock it in place.
For more information on how to install/remove AMC/Drives, see “Replace an AMC/Disk Drive” on
page 49.
Figure 17. Installing an AMC/Drive into the LPC
Note: The AMC/Drives can be installed in any order in the LPC slots during the
initial set up of the chassis. After the chassis is powered on for the first time, the
drives will be formatted and configured with two RAID 1 pairs.
OWER
ACTIVI
TY
FAULT
POWER
PA-700
-AMC-1TB
ACTIVI
TY
FAULT
PA-700
-AMC-1TB
Pull this lever outward when installing
and then push all the way in after the
AMC/Drive is inserted into the LPC.
This will lock the AMC/Drive in place.