3
GENERAL INFORMATION
SPECIFICATIONS
The ThermoFlo unit is available in either the 115 VAC or 230 VAC version. The 115 VAC version system bears the
FCC Conformity Marking which assures the user that it conforms to all the requirements of FCC Emission Control
Standard, Title 47, Subpart B, Class A. The 230 VAC version system bears the CE Conformity Marking which
assures the user that it conforms to all the requirements of (EU) directive EMC 89/336/EEC & 73/23/EEC.
Available ThermoFlo Configurations
TF 200 Unit -
Utilizes PPS 95 Power Source (115VAC) plus tools and accessories.
TF 200E Unit -
Utilizes PPS 95E Power Source (230VAC) plus tools and accessories.
TF 500 System -
Utilizes PPS 95 Power Source (115VAC), work platform, board holder, tools and accessories.
TF 500E System -
Utilizes PPS 95E Power Source (230VAC),work platform, board holder, tools and accessories.
PRC 1500 System -
Utilizes PPS 95 Power Source (115VAC), MBT 250A system, tools and accessories.
PRC 1500E System - Utilizes PPS 95E Power Source (230VAC), MBT 250AE system, tools and accessories.
Power Requirements
PPS 95 Power Source
-
Operates on 97-127 VAC, 60 Hz
(115 VAC version)
575 Watts maximum at 120 VAC, 60 Hz
PPS 95E Power Source
-
Operates on 197-264 VAC, 50 Hz
(230 VAC version)
575 Watts maximum at 230 VAC, 50 Hz
Air Temperature Range - 93°C - 427°C (200°F - 800°F)
Timing Control - 10 to 999 seconds with 1 second resolution. (does not include preheat time)
Blower Air Flow Rate (measured at heater) - 25 SLPM (0.9 SCFM) minimum at maximum speed (9).
Blower Life & Operation - 1500 hours minimum when operated with duty cycle of 3 minutes on/3
minutes off.
NOTE
The ThermoFlo is designed for cyclical useage. Attempts to use in
continuous operations by taping the handpiece Cycle Switch or other
methods will void Blower Assembly warranty.
Component Capacity - (maximum size) - 5.1 cm x 5.1 cm (2” x 2”)
Physical Parameters
Size - 135 mm H x 165 mm W x 260 mm D (5.3” H x 6.5” W x 9.25” D)
Unit Weight - 4.5 Kg. (9.8 lbs.)
Summary of Contents for PROGRAMMABLE THERMOFLO
Page 2: ...i MANUAL NO 5050 0420 REV A...