66
OPERATION
Figure 88.
ENTERING/EDITING A PROFILE CONT'D
18. "Reflow Time =" is now displayed. A number
depicting the amount of time in seconds is shown on
the bottom line of the Digital Readout. Use the
numbered keys to enter the desired time (10 seconds
minimum). Always enter 3 numbers to obtain the
correct display. Press and release the STEP Key.
19. If the Profile being entered/changed is a Removal
profile, proceed to step 20. A"Vacuum Release Time
=" is now displayed if the Profile being entered (or
changed) is an Installation profile. A number
depicting the amount of time (in seconds) into the
Reflow cycle before the vacuum stops (to drop the
component on the PCB). Use the numbered keys to
enter the correct number (5 seconds minimum and
must be at least 5 seconds less than the Reflow cycle
time). Always enter 3 numbers to obtain the correct
display. Press and release the STEP Key.
Figure 89.