52
OPERATION
PROGRAM COMPONENT REMOVAL CONT'D
8. Press and release the CYCLE Key or Cycle Switch
(on handpiece).
9. If the selected profile includes a lower preheat cycle,
the Digital Readout will display "HeatWave =
XXX°" (set preheat temperature). Check the
temperature of the Heat Wave system (Digital
Readout on Heat Wave power source front panel).
If the Heat Wave is at temperature, press and release
the YES Key. The cycle will now activate and
automatically step through the profile.
If the Heat Wave is not at temperature:
Wait until the Heat Wave reaches set temperature,
then press and release the YES Key to activate the
cycle.
or
Press and release the NO Key, then repeat steps 8 &
9 after the Heat Wave reaches set temperature.
NOTE
Once the cycle is initiated, the cycle can be quickly terminated at any time
by simply pressing and releasing the CYCLE Key or Cycle Switch (on
handpiece).
10. The unit will now cycle through the programmed profile and display the step (e.g., top preheat, reflow,
soak, cool down), temperature and count down time. At the end of each step in the process, the unit
will sound a beep tone.
Figure 61.
Figure 60.