86
DISPENSING SUGGESTIONS
1. Dispose of all tips and barrels after use. Always use new tips and barrels to prevent
contamination, insure cleanliness and provide consistent, repeatable material deposition.
2. When dispensing different dot sizes, select a tip/time combination which dispenses small dots.
These small dots may be dispensed in multiples to provide the deposition amount required.
Use of the feature in this manner can eliminate frequent tip changes and dispense cycle time
adjustments.
3. In situations where the metal tip may scratch or damage the work, install a short section of
heat shrinkable tubing or teflon sleeving. The tubing (or sleeving) should extend 1.5 mm (1/16")
past the tip end.
4. Keep all dispenser components clean to prevent clogging and/or irregular deposition.
VACUUM PICK
SET-UP
1. Locate the Pik-Vac (P/N 7027-0001-P1) and the Vacuum Cup Kit (P/N 6993-0154) supplied with
the system.
2. Attach the ridged end of a male quick connect hose
mount Fitting to each end of the Air Hose.
Air Hose
Fitting
Figure 108. Air Hose Set-Up
Summary of Contents for PRC 2000