41
NOTE
Refer to “Tip & Temperature Selection” for a complete discussion of Tip
Temperature Offset function.
10. Press the
TIP OFFSET
Key once to enter
TIP
OFFSET
Mode. Immediately press and hold the
Scroll Up Key. Observe the displayed TIP OFFSET
CONSTANT increase, first in 1° and then in 10°
increments. Release the Scroll Up Key when the
Digital Readout reads “33” for °C (“60” for °F).
NOTE
If the Digital Readout displays "P - -", a pass-
word has been previously installed. Enter the
password at this point to continue. Refer to the
"Password" portion of this manual for details on
password operation.
11. While still in the
TIP OFFSET
Mode (
TIP OFFSET
LED flashing) press and hold the Scroll Down Key.
Observe the displayed TIP OFFSET CONSTANT
decrease first in 1° and then in 10° increments.
Release the key when the Digital Readout displays
“28” for °C (“50” for °F).
12. Immediately press the
TIP OFFSET
Key to exit the
TIP OFFSET
Mode and enter the new TIP OFFSET
CONSTANT for the Current Channel into the system
memory. Notice that the
TIP OFFSET
LED remains
illuminated (not flashing). ONLY IF A CURRENT
CHANNEL HAS A TIP OFFSET CONSTANT
GREATER THAN THE DEFAULT (“3” for °C or “6” for
°F) DOES THIS LED REMAIN ILLUMINATED. The
system will retain stored Set Tip Temperatures and
TIP OFFSET CONSTANTS even when power is
removed.
Figure 31. Increase Tip Offset Value
Figure 33. Store Tip Offset Value
Figure 32. Decrease Tip Offset Value
Summary of Contents for PRC 2000
Page 1: ...1 SYSTEM OPERATION MAINTENANCE MANUAL PRC 2000 SYSTEMS ...
Page 2: ...2 ...
Page 3: ...3 MANUAL NO 5050 0313 REV G ...
Page 17: ...17 Figure 6 Thermal Management Center ...
Page 23: ...23 Figure 12 Pik And Paste Section ...
Page 74: ...74 ...
Page 95: ...95 Figure 122 Pulse Plate Set Up ...
Page 96: ...96 ...
Page 102: ...102 ...
Page 111: ...111 ...
Page 119: ...119 ...