105
NOTE
Perform the "Heater Assembly Checkout Procedures" shown below with the
handpiece (and heater) at room temperature. If the handpiece is warm,
resistance reading will be different from those shown in the table below.
SYMPTOM
CHECKOUT PROCEDURE
CAUSE
SOLUTION
HEATER
SPECIFICATIONS
No heat
Check resistance - Pin 2 to Pin 5.
Refer to "Heater Specifications"
column.
If resistance is high - -
Open Heater
Replace Heater
Assembly.
SX-70
SP-1A
SP-2A
TP-65
TJ-70
= 8 - 10 ohms
= 10 - 12 ohms
= 8 - 10 ohms
= 9 - 11 ohms
= 6 - 8 ohms
Check resistance - Pin 3 to Pin 6.
If circuit reads open - -
Open Sensor
Replace Heater
Assembly.
Handpiece
overheating
Check resistance - Pin 3 to Pin 6.
Resistance should be 110 ohms.
If resistance reading is less than
105 ohms - -
Shorted Sensor
Replace Heater
Assembly.
Fuse blows
when unit is
turned on.
Check resistance - Pin 2 to Pin 5.
Refer to "Heater Specifications"
column.
If resistance is low - -
Solder short in
Handpiece.
Remove Short.
Replace Heater
Assembly & Fuse F1.
Shorted Heater
Replace Heater
Assembly & Fuse F1.
No Ground
on Tip.
Check resistance - Pin 4 to a
NEW Tip. Resistance should be
less than 2 ohms.
If not - -
Oxidation buildup
in Heater Bore.
Clean Heater Bore
using appropriate wire
brush.
Defective Heater
Replace Heater
Assembly.
Table 6. Heater Assembly Checkout Procedures
Summary of Contents for PRC 2000
Page 1: ...1 SYSTEM OPERATION MAINTENANCE MANUAL PRC 2000 SYSTEMS ...
Page 2: ...2 ...
Page 3: ...3 MANUAL NO 5050 0313 REV G ...
Page 17: ...17 Figure 6 Thermal Management Center ...
Page 23: ...23 Figure 12 Pik And Paste Section ...
Page 74: ...74 ...
Page 95: ...95 Figure 122 Pulse Plate Set Up ...
Page 96: ...96 ...
Page 102: ...102 ...
Page 111: ...111 ...
Page 119: ...119 ...