35
NOTE
If more than one air-operated handpiece is connected to the
THERMAL
MANAGEMENT CENTER
, insure that only one of the Air Hoses is
connected to either the
SNAP-VAC
Port or Controllable
PRESSURE
Port.
Attachment to both simultaneously will cause a deterioration in perfor-
mance.
QUICK CONNECT METHOD
May be used with any SensaTemp handpiece except TJ-70 Mini ThermoJet.
1. Prepare a VisiFilter in the following manner.
a) Connect a 1 inch (2.5cm) length of clear pvc Air
Hose to each side of the VisiFilter; push and turn
hose onto VisiFilter nipple to seat.
b) To the free end of the Air Hose connected to the
FLOW IN side of the VisiFilter, insert the ridged end
of a female quick connect hose mount Fitting (P/N
1259-0086).
c) Insert the ridged end of a male quick connect hose
mount Fitting (P/N 1259-0087) in the free end of the
Air Hose connected to the FLOW OUT side of the
VisiFilter.
2. Insert male quick connect hose mount Fitting
(attached to VisiFilter assembly) into female
SNAP-
VAC
Port on front panel of power source.
Figure 22. VisiFilter Preparation
Summary of Contents for PRC 2000
Page 1: ...1 SYSTEM OPERATION MAINTENANCE MANUAL PRC 2000 SYSTEMS ...
Page 2: ...2 ...
Page 3: ...3 MANUAL NO 5050 0313 REV G ...
Page 17: ...17 Figure 6 Thermal Management Center ...
Page 23: ...23 Figure 12 Pik And Paste Section ...
Page 74: ...74 ...
Page 95: ...95 Figure 122 Pulse Plate Set Up ...
Page 96: ...96 ...
Page 102: ...102 ...
Page 111: ...111 ...
Page 119: ...119 ...