30
13.x Circuit 2.
13.1 Circulation mode 2
– This parameter allows you to attach the second circuit,
and choose whether this mode is to be operated stirrer with a pump or the pump
itself.
13.2 Mode switching circuit 2 –
when working in a mixing valve pump:
TERM
– the pump runs continuously. The mixing valve keeps the temperature of the
second cycle in depending on the characteristics of the weather and room tempera-
ture.
AUTO
– the pump runs continuously. The mixing valve keeps the temperature of the
second circuit only depending on the characteristics of the weather
Mode switching circuit 2
– when working in the system only the pump:
TERM –
thermostat controls the operation of the pump.
AUTO –
Continuous pump operation.
13.3 Weather control
– This function allows you to attach a weather control.
13.4 Temperature set point circuit
– the temperature is maintained behind the
mixing valve.
13.5 Lowering the thermostat
– in the case of opening the contacts of thermostat
temperature the second circuit is reduced by the value set in this parameter.
13.6 Increasing the temperature of the boiler
– circulation set tempe the
value of raising the temperature of the boiler - this is the minimum boiler temperature
that will be set on the boiler.
13.7 The hysteresis circuit 2
– parameter determines how much the temperature
must fall the second circuit to control heat attached.
13.8 The minimum temperature circuit 2
– The minimum temperature is maintai-
ned at a second circuit.
13.9 Maximum temperature circuit 2
– The maximum temperature that can be
reach the second circuit