24
6.5 Opening time cleaning mechanism
– this parameter is only available when
cleaning mechanism operates in AUTO mode or ESTATE and determines the time
required to complete the opening mechanism during cleaning automatic.
6.6 Closing time cleaning mechanism
– This parameter is available only when the
cleaning mechanism operates in AUTO mode or COMBI and determines the time it
takes to return the mechanism to its rest position after the full opening of the automa-
tic cleaning mechanism.
6.7 Number of extinctions before cleaning
– this parameter is available only when
the cleaning mechanism operates in AUTO mode or COMBI and determines which in
turn goes off to start the procedure of cleaning.
6.8 Minimum operating time without cleaning
– this parameter is available only
when the cleaning mechanism operates in AUTO or COMBI mode. Specifies the mi-
nimum number of hours the burner must in order to start cleaning. If the minimum ti-
me is not reached, the cleaning will not run even if there was a required number of
shut downs. Setting the parameter to „0h" control the minimum time off work without
cleaning.
6.9 The maximum working time without cleaning
– this parameter is available on-
ly when the cleaning mechanism operates in AUTO or COMBI mode. Specifies how
many hours the burner can work without cleaning. If the maximum time is reached,
the cleaning will run even if there was no required number of shut downs.
6.10 Number of repeats
– allows the user to set the number of cleaning mechanism
movements forth and back while the entire cleaning in the 'perfect' mode.
6.11 Burner mode.
Continuous
– the power of the burner is reduced after the defined working time and
the ash-removal occurs.
Intermittent
– the ash-removal occurs at the end of the burning cycle.
.
7.x Central heating pump work parameters.
7.1 Central heating pump switching on parameters
– this parameter specifies the
method of central heating pump switching on. Selection of „THERMOSTAT” setting
means that central heating pump will be switched on only if room thermostat contacts
are closed and in case of emergency (e.g. boiler overheating). Selection of „AUTO”
setting means that central heating pump operation will follow regardless of room
thermostat.