17
13.10 The time of the actuator.
2s
99s
13.11 Actuator pause time.
0s
99s
13.12 The transit time of the actuator.
1min
10min
13.13 Circuit type 2: CENTRAL, UNDERFLOOR.
13.14 Use the main thermostat .
NO
YES
14.x
The heating
curve
14.1 Outside temperature sensor IS, NO
14.2 Point 0 heating curve.
20°C
80°C
14.3 Moving the curve.
0°C
20°C
2.x Oveall.
2.1 Language selection
– RK-2006SPGM controller interface offer the function of
language selection. Number of available languages depend on software version
being used.
2.2–2.4 Brightness, saturation, contrast of the display –
the parameters enable
the user to adjust the display to his/her own needs.
2.5 Service settings
– setting and confirm with the OK button to display the value
YES when this option will delete all the parameters and assign them to the pre-pro-
grammed by the installer or service technician.
2.7 Testing out
– in order to verify the correctness of the controller, it is possible to
test various output devices. This feature is available in service mode only if the adju-
stment process is stopped, ie. The regulator before entering the service mode was in
STOP mode. Selecting output testing allows the control knob to select the outputs
on the display. Pressing OK allows you to temporarily attach the selected output. In
order to complete the testing procedures exit, press the STOP button.
3.x Fan operation parameters.
3.1 Fan modulation during boiler start
– selection of „YES” setting means that fan
speed modulation will be provided during boiler start.
3.2 Min. fan speed during heating up
– this parameter is available, if the function
of fan modulation during boiler start is selected. This parameter specifies power of
the fan during boiler start.
3.3 Max. fan speed during heating up
– this parameter is available, if the function
of fan modulation during boiler start is selected. This parameter specifies power of
the fan at end of boiler start.
3.4 Ignition modulation start delay
– this parameter is available, if the function of
fan modulation during boiler start is selected and it describes operation time of the
Summary of Contents for RK-2006SPGMS
Page 2: ......
Page 34: ...34 Figure RK 2006SPGMS Controller connection diagram...