E-025-2-E
3.6.6 Device Information (Device information)
① Click "Setup (S)" from the menu, and select "Device information", then the following window
(Fig. 57) will be displayed.
Fig.57
② Select or enter characters or numeric values for respective items.
Setting item
Detail
Setting range
Tag
Tag number of meter
8 alphanumeric characters
Descriptor
Description
16 alphanumeric characters
Message
Message
32 alphanumeric characters
Date
Month/Day/Year
Month, Day and Year, each represented in 2
digits of positive integer
Device ID
Device ID of transmitter
0 to 16777215 (Only for reference)
Sensor serial No.
Sensor serial number
0 to 16777215 (Only for reference)
Final assembly No.
Transmitter manufacturing
number
0 to 16777215 (Only for reference)
Flange type
Flange type (Select from the
right column.)
JIS 10K, JIS 20K, JIS 30K, ANSI/ASME150,
ANSI/ASME300, Flangeless, Sanitary, Union, Special
Flange material
Flange material (Select from the
right column.)
Carbon Steel, 304 Stainless Steel, Special
Liner material
Liner material (Select from the
right column.)
PTFE, Ceramic, PFA, ETFE, Soft Gum,
Hard Gum, Special
Electrode type
Electrode type (Select from the
right column.)
Standard, Replaceable, Special
Electrode material
Electrode material (Select from
the right column.)
Alloy C276, Tantalum, 316L Stainless Steel,
Platinum Special
Universal rev.
Communication protocol revision Only for reference
Device rev.
Device revision
Only for reference
Software rev.
Software revision
Only for reference
Hardware rev.
Hardware revision
Only for reference
System rev.
System revision
Only for reference
Main CPU rev.
Main CPU revision
Only for reference
LCD CPU rev.
Display CPU revision
Only for reference
I/O CPU rev.
Input/Output CPU revision
Only for reference