PRODUCT OVERVIEW
2
OI-6000-X-X-X-X-O OPS_GUIDE_REV 3.1
1.2
PRODUCT SPECIFICATIONS
System Specifications
Operating Voltage
+12 to +35 VDC
Current Draw
250 mA Maximum
Operating Temperature Range
-40
⁰
C to +54
⁰
C
Humidity Range
0% to 98% Relative Humidity, Noncondensing
Measurement Range
Varies based on gas type
Response Time
Varies based on gas type
Protection
Power Electromagnetic Interference (EMI) Filter
4-20 mA Surge Suppression
RS-485 Modbus Surge Suppression
Display
Transflective (sunlight-readable)
102x64 LCD Screen
LED Back-Light
Interface
3 Push-Buttons (MENU, ADD, SUB)
3 Magnetic Switches for Non-Intrusive Operation
LOW and HIGH Alarm Indicator LEDs
Outputs
Wired (Analog)
4-20 mA (3-Wire)
Wired (Digital)
RS-485 Modbus RTU
WireFree (Optional)
GEN II 900 MHz or GEN II 2.4 GHz
Relays (Optional)
Two Dry Contact Relays with Replaceable 4 Amp Fuses
.
Mechanical Specifications
Enclosure Materials
Aluminum Device Enclosure
Sensor Housing Materials
303 Stainless Steel Sensor Housing
Product Dimensions
5.5” T x 6” W x 7” H (8” W x 17” H Maximum w/ Antenna Fitting and Antenna)
Product Weight
6 lbs.
Safety Approvals
Enclosure Ratings
Explosion/Flame-Proof
Hazardous Location Certification
Class I, Division 1, Groups C and D, T6
Ex d IIB T6
Zone 1, AEx d IIB T6
Tamb -40
⁰
C to +54
⁰
C