C
ONNECTING
THE
W
ELDING
P
OWER
S
OURCE
C
ONNECTION
C
HAPTER
4
34
4.2.2
Connection of wire feeder
This chapter explains the connecting procedure of the wire feeder. Refer also to the instruction manual of wire feeder.
T I P S
•
When using the voltage detection cable, the wiring for the wire feeder or welding power source needs
to be changed. (
4.6
-
Wiring of Voltage Detection Cable at Base Metal Side)
1.
Remove the right side panel of the wire feeder.
2.
Connect the power cable for wire feeder (torch side) to the M10 terminal.
●
Secure it with a nut so that there is no looseness at the terminal.
●
Avoid any washer or spring washer from getting caught between the crimp terminals.
3.
Remove the cap of the socket of wire feeder and insert the control cable (10 cores) to the socket for the wire
feeder.
●
Fit the concave part of the connector and convex part of the socket for secure connection and tighten the knurled
screws in the clockwise direction.
●
When using an analog remote control (optional accessory), remove the cap of socket for analog remote control
and insert the control cable (6 cores).
4.
Restore the right side panel of the wire feeder.
Connection for wire feeder is complete. Procedure is followed by “4.2.3
-
Connection of welding torch”.
CAUTION
•
When not using an analog remote control (optional accessory), do not remove the cap for
the analog remote control.
Welding power source
Socket for the wire feeder
Socket for
analog remote control
Control cable of
analog remote control
Analog remote control
(Optional accessories)
Control cable for
wire feeder
Wire feeder
M10 terminal
Cable fixture
Connector
Nut
Power cable for
torch side
Power cable for
base metal side
Power cable for
torch side