F
UNCTION
ON
O
PERATION
P
ANEL
W
ELDING
C
ONDITION
C
HAPTER
6
66
6.2 Function on Operation Panel
This section explains the function of displays and keys arranged on the operation panel.
6.2.1
Operation panel
F86
Current display adjustment
(GAIN)
-20 to 20
0 (%)
These functions are for adjusting current value
displayed on the digital meter.
-
F87
Current display adjustment
(OFFSET)
-20 to 20
0 (A)
F88
Voltage display adjustment
(GAIN)
-20 to 20
0 (%)
These functions are for adjusting voltage value
displayed on the digital meter.
-
F89
Voltage display adjustment
(OFFSET)
-2.0 to 2.0
0.0 (V)
*1: WB-P402L
*2: WB-P502L
No.
Name
Function
1
Left digital meter
Displays various information.
•
The welding current is displayed in welding, and the LED of "A" lights up.
•
In each setting, corresponding setting values are displayed, and the LED lit position
automatically switches.
2
Right digital meter
Displays various information.
•
The welding voltage is displayed in welding.
•
In each setting, corresponding setting values are displayed, and the LED lit position
automatically switches.
No.
Function Name
Setting range
Initial value
Explanation
Memory
15
8
7
6
5
4
1
2
3
16
17
5
14
13
12
11
10
9
18
UNIT CHANGE key
DISPLAY CHANGE key
Screen operation knob
Parameter adjusting knob