L
IST
OF
W
ELDING
C
ONDITIONS
W
ELDING
C
ONDITION
C
HAPTER
6
64
F45
Special crater
sequence
OFF/ON
OFF
Sets the initial condition and crater condition as applied
for a fixed period of time regardless of the torch switch
operation:
OFF: Not applied
ON: Applied (Time set by F46 and F47 is applied)
㾎
F46
Special crater sequence
initial time
0.0 to 10.0
0.0 (s)
Sets initial time in the special crater sequence.
(available when "ON" is selected in F45)
㾎
F47
Special crater sequence
crater time
0.0 to 10.0
0.0 (s)
Sets crater time in the special crater sequence.
(available when F45 is enabled)
㾎
F48
Adjusting current with torch
switch
OFF/ON
OFF
With the setting of "Crater" and in the welding condition
(during start input holding), sets whether to adjust
current by the torch switch operation:
OFF: not to use torch switch
ON: uses torch switch (increase/decrease volume set
by F49 and F50 are applied).
㾎
F49
Current increase and
decrease by single-clicking
-100 to 100
0 (A)
Sets current increase/decrease volume by single
clicking of the torch switch. (available when "ON" is
selected in F48)
㾎
F50
Current increase and
decrease by double-clicking
-100 to 100
0 (A)
Sets current increase/decrease volume by double-
clicking of the torch switch. (available when "ON" is
selected in F48)
㾎
F51
Special crater repeat
OFF/ON
OFF
With the setting of "Crater," sets whether to switch the
welding condition and crater condition by the click
operation of the torch switch:
OFF: not to use torch switch
ON: uses the torch switch
㾎
F52
Data type of data log
function
0 to 8
0
Sets sample data on the data log:
0: No sampling
1: Welding current / Welding voltage / Sequence
information
2: Current command / Voltage command / Feeding
command
3: Current command / Welding current / Welding
voltage
4: Current command / Welding current / Sequence
information
5: Welding current / Voltage command / Welding
voltage
6: Voltage command / Welding voltage / Sequence
information
7: Welding current / Feeding command / Sequence
information
8: Welding voltage / Feeding command / Sequence
information
-
F53
Sampling speed of data log
function
1/2/3
1
Sets sampling interval of the data log function:
1: 10ms
2: 100ms
3: 1s
-
F54
Tack start process
OFF/ON
OFF
Sets whether to feed the wire with the slowdown speed
at the time of welding start:
OFF: Feeds with slow down speed
ON: Feeds without slow down speed
-
F55
Arc loss detection time
OFF (fixed)
OFF
Used when connecting with OTC automatic machine.
-
F56
Arc start error
detection time
F57
WCR output ON
delay time
F58
WCR output OFF
delay time
F59
Analog setting switch
F60
Pulse peak current fine
adjustment
-150 to 150
0 (A)
Sets the adjustment value of pulse peak current in pulse
welding.
㾎
F61
Pulse peak time fine adjustment
-1.5 to 1.5
0.0 (ms)
Sets the adjustment value of pulse peak time in pulse
welding.
㾎
F62
Base current fine adjustment
-60 to 60
0 (A)
Sets the adjustment value of base current in pulse
welding.
㾎
No.
Function Name
Setting range
Initial value
Explanation
Memory