73
Chapter 6
W
elding Condition
M
EMORY
F
UNCTION
OF
W
ELDING
C
ONDITIONS
W
ELDING
C
ONDITION
C
HAPTER
6
2.
Turn the screen operation knob (or parameter adjustment knob), and select the JOB No. to read out.
3.
Press the screen operation knob.
4.
Press the screen operation knob.
⇒
The welding condition is registered with the selected JOB No., and the read mode is terminated.
⇒
The selected position on the operation panel and the current/voltage values are overwritten to those read out.
6.5.3
Deletion of memory registration
This section explains how to delete the welding conditions registered to the memory.
NOTE
• The deleted data cannot be restored. Before deleting the stored welding condition, carefully check the
welding JOB No. to delete.
1.
Turn OFF the power switch.
2.
With the two DISPLAY CHANGE keys depressed together, turn ON the power switch.
⇒
When there is no registration data on the selected JOB No.,
“no data” is displayed on the LCD panel and "- - - -" is
displayed on the left digital meter.
⇒
When there is any registration data on the selected JOB
No., the setting value of the welding current is displayed
on the left digital meter. At this time, the setting values of
crater or wire material also display on the LCD panel.
⇒
The setting values are displayed on the left/right digital
meters in a flashing mode.
⇒
Pressing the DISPLAY CHANGE key enables to check the
set values of welding conditions (welding parameters) to
read out. The setting values are displayed on the left/right
digital meters in a flashing mode.
•
To change the JOB No. to read out, pressing the CANCEL key to return
to the status described in step 1.
●
Depress these two keys until "USER MENU" is displayed
on the LCD panel. Release the keys after "USER MENU" is
displayed.
ON
+
+
&DOLEUDWLRQ0RGH
'HOHWH-2%
3DVVZRUG6HWWLQJ
86(50(18
6(/(&7