SECTION 7 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE
31215054
7-17
NOTE:
Machines may be built with either Bonfiglioli or Reggiana Ridut
-
tori wheel drive hubs.
4.
A: Wheel Drive Hub
Lube Point(s) - Level/Fill Plug
Capacity - 2.1 quarts (2 liters) ± 10%
Lube - EPGL
Interval - Change after first 150 hours then every 1200 hours of
operation
Comments - Place Fill port at 12 o’clock position and Check
port at 8 o’clock position. Pour lubricant into fill port until it
just starts to flow out of check port.
B: Wheel Drive Hub - Reggiana Riduttori
Lube Point(s) - Level/Fill Plug
Capacity - 0.5 quarts (0.5 liters) ± 10%
Lube - EPGL
Interval - Change after first 150 hours then every 1200 hours of
operation
Comments - Place Fill port at 12 o’clock position and Check
port at 3 o’clock position. Pour lubricant into fill port until it
just starts to flow out of check port.