SECTION 6 - ACCESSORIES
31215054
6-15
5.
Ensure the area below the platform is clear of obstructions
and lower the platform. The machine should slow down,
(SkySense Status LED will blink yellow with increasing fre
-
quency) and stop, (SkySense Status LED will be illuminated
solid red) when the bottom of the platform is approximately
12 inches from the ground. The alarm should sound if it is
not muted (refer to SkySense Alarm).
6.
Recycle the footswitch and press the override button on the
platform control console.
7.
Continue to lower the platform. The machine should move
in the elevated drive speed mode (SkySense Status LED will
remain red).
NOTE:
The SkySense system will not stop machine operation while in
Creep.
Operation
SkySense slows a machine’s function to creep speed when it is a
certain distance away from an object, known as the "warning
zone." If the machine continues to approach the object and
moves into the "stop zone," SkySense stops all machine functions.
For proportional functions activated by the joystick, the size of
the warning zone varies based on the amount of joystick activa
-
tion. The stop zone always activates at the same distance from
the object regardless of the joystick’s position.
If the function has reached the warning zone, normal drive speed
will resume when a function is activated in the opposite direc
-
tion. If the machine has reached the SkySense stop zone, release
the function and recycle the footswitch to activate a function in
the opposite direction.
SkySense is active during the following functions:
• Lift Up/Down (including jib functions)
• Platform Rotate (including jib rotate)
• Telescope Out
• Swing
• Reverse Drive
Summary of Contents for JLG 1200SJP
Page 10: ...iv 31215054 TABLE OF CONTENTS...
Page 12: ...vi 31215054 LIST OF TABLES...
Page 14: ...viii 31215054 LIST OF FIGURES...
Page 62: ...SECTION 3 MACHINE CONTROLS AND INDICATORS 3 24 31215054...
Page 110: ...SECTION 5 EMERGENCY PROCEDURES 5 4 31215054...
Page 132: ...SECTION 6 ACCESSORIES 6 22 31215054...
Page 164: ...SECTION 7 GENERAL SPECIFICATIONS OPERATOR MAINTENANCE 7 32 31215054...
Page 167: ......