SECTION 4 - MACHINE OPERATION
31215054
4-15
Standstill Cleaning
Levels
Machine Hours
Since Last
Cleaning
Engine Error
Indicator
DPF Indicator
Emissions
Temperature
Indicator*
Derate
Comments
0
Normal
Operation
0-500
- -
- -
None
Between 500 and 650 hours,
cleaning cycle can be initiated
with JLG analyzer.
500-650
1
Standstill
Required
650-750
- -
None
Engine coolant temperature
must be >40° C and machine
must be in ground station
mode.
2
Warning
Level
750-775
Continuous
Machine placed in Creep
and DTC active
3
Shut Off
Level
>775
Blinking
Idle Lock. Boom Func
-
tions Locked Out and
trapped in Transport.
Contact Deutz Dealer
4
Filter
Exchange
DPF Regeneration
NOT POSSIBLE
DPF Filter exchange
required
Blinking
Idle Lock. Boom Func
-
tions Locked Out and
trapped in Transport.
*Emissions Temperature indicator continuously ON during Standstill Cleaning