SECTION 4: INSTALLATION
CAS40P 40 CFM / 100 PSIG
PAGE - 14
®
An Oshkosh Corporation Company
• The mounting surface must be level and able to
accommodate the four [4] mounting bolts of the base
frame. Refer to
Figure 4-1
.
• The mounting surface must be able to support the
unit’s weight (400 lbs.).
• The location must allow for the machine dimensions
(
Figure 4-2
), and additional space requirements for
minimum cooling, maintenance and access. Refer to
Figure 4-3
to determine the additional minimum
space requirement measurements.
• The external gauges must be easily visible to the
operator.
It is recommended, for most installations, to mount the
compressor on the driver’s side of the vehicle. The unit
should be situated in such a manner that the fan (rear)
and hydraulic cooler (front) are not obstructed. Do not
place the compressor in any location where it can ingest
exhaust fumes, dust or debris.
KEY
DESCRIPTION
KEY
DESCRIPTION
A
0.75 inches
D
1.25 inches
B
30.5 inches
E
18.56 inches
C
MOUNTING SLOT Ø0.56 X 1.25 inches (x 4)
NOTE:
For additional machine measurements, consult
Figure 4-2
.
Figure 4-1: Base Frame Mounting and Hole Locations
A
D
E
B
C
C
C
C
Manual #99905382 Rev 02
(JUNE 2018)
Summary of Contents for IMT CAS40P
Page 119: ...BLANK PAGE...