background image

Operation Manual

12 V, 17 bar (250 psi) Air Compressor 

61489

Illustration similar, may vary depending on model

Read and follow the operating instructions and safety information before using for the first time. 

Technical changes reserved!
Due to further developments, illustrations, functioning steps and technical data can differ insignific-
antly.

Updating the documentation
If you have suggestions for improvement or have found any irregularities, please contact us.

Summary of Contents for 61489

Page 1: ...operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignific antly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us ...

Page 2: ...anguages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our pick up address is WilTec Wildanger Technik GmbH Königsbenden 28 52249 Eschweiler Germany To shorten the waiting time and allow for a rapid on site transaction we ask you to call us previously or pla...

Page 3: ... the thumb lash 4 When the desired pressure is reached unplug the power cord 5 Remove adaptor from tire valve remove the power cord from the cigarette lighter 6 Always leave the thumb latch in the open position when storing the compressor Inflating other inflatable objects Sports ad aptor Adaptors for mattresses rubber boats etc Lock valve stem connector Select the suitable adaptor and insert it i...

Page 4: ...ttings Compressor runs slowly Overheated from excessive use Unplug the power cord and leave the compressor to cool down for at least 30 min Voltage too low Check condition of battery CAUTION This compressor is capable of inflating to 17 bar 250 psi To avoid over inflation the user has to strictly follow operating instructions as required and described Do not exceed the recom mended pressure at any...

Page 5: ...ints out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equip ment By contributing to the correct disposal of this art icle you protect the environment and the health of your fellow men Environment and health are threatened by inappropriate disposal Material recycling helps reduce the consum...

Reviews: