1 Introduction
−
3
−
System configuration
Operating the
CSK
series requires a controller equipped with a pulse output
function.
DC power input
Controller
Digital I/O
Motor
Driver
As for the voltage supply to the driver, use an EMC-compliant DC power supply
with reinforced insulation on both the primary and secondary sides.
Compliance with the EC Directives
If compliance with the European Low Voltage Directive and EMC Directive is
required, the user is advised to take full responsibility for the following measures:
The installation conditions that must be satisfied to meet the above directives are as
follows:
•
Install the motor and driver inside an enclosure.
•
Use an EMC compliant DC power supply with reinforced insulation on both the
primary and secondary sides.
•
Provide protective earthing for the DC power supply.
•
Use shielded cable for I/O cables.
•
Use a mains filter.
•
For Low Voltage Directive (73/23/EEC)
The
CSK
series motors and drivers are not subject to the Low Voltage Directive,
since their input power supply voltage is 36 VDC or below. However, the product
must satisfy the following conditions with regard to installation and connection:
•
Use the product in a protected environment within an enclosure.
•
As for the driver’s and digital I/O signal’s power supply, use a DC power supply
with reinforced insulation on both the primary and secondary sides.
Motor
Driver
Degree of protection
IP20
IP00
Installation conditions
Built-in component
Overvoltage category: I
Pollution degree: 2
Protection against electric shock: Class III equipment