5 Installation
−
20
−
CSD2140T
,
CSD2145T
Mount the driver to the mounting plate using No.4-40 UNC screws.
•
Horizontal installation
Mounting
plate
No.4-40 UNC
screw
•
Vertical installation
Mounting
plate
No.4-40 UNC
screw
5.6 Installing and wiring in compliance with EMC
Directive
Effective measures must be taken against the EMI that the
CSK
series may give to
adjacent control-system equipment, as well as the EMS of the
CSK
series itself, in
order to prevent a serious functional impediment in the machinery. The use of the
following installation and wiring methods will enable the
CSK
series to be
compliant with the EMC Directive (the aforementioned compliance standards).
The compliance of the final machinery with the EMC Directive will depend on such
factors as the configuration, wiring, layout and risk involved in the control-system
equipment and electrical parts. It therefore must be verified through EMC measures
by the customer of the machinery.
Applicable standards
EMI Emission
Tests
Radiated Emission Test
EN 61000-6-4
EN 55011
EMS Immunity
Tests
Radiation Field Immunity Test
Fast Transient / Burst Immunity Test
Conductive Noise Immunity Test
EN 61000-6-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-6
•
About power supply
The
CSK
series products are of the DC power supply input specification. Use a DC
power supply that is optimally compliant with the EMC Directive.