IO data
99
4 PR
OFINE
Details of Input data
z
Remote I/O (R-OUT)
This is the I/O accessed via PROFINET.
The assignments of signals can be changed using the “R-OUT output function” parameters.
Byte
Bit
Name
Description
Initial assignment
1
0
R-OUT0
A response to a signal assigned with the
“R-OUT output function” parameter is
output.
64: M0_R
1
R-OUT1
65: M1_R
2
R-OUT2
66: M2_R
3
R-OUT3
32: START_R
4
R-OUT4
144: HOME-END
5
R-OUT5
132: READY
6
R-OUT6
135: INFO
7
R-OUT7
129: ALM-A
0
8
R-OUT8
136: SYS-BSY
9
R-OUT9
160: AREA0
10
R-OUT10
161: AREA1
11
R-OUT11
162: AREA2
12
R-OUT12
157: TIM
13
R-OUT13
134: MOVE
14
R-OUT14
138: IN-POS
15
R-OUT15
140: TLC
z
Operation data number selection_R
Byte
Bit
Name
Description
3
0
M0_R
A response to an input signal is output.
1
M1_R
2
M2_R
3
M3_R
4
M4_R
5
M5_R
6
M6_R
7
M7_R
2
8 to 15
Reserved