Parameter R/W commands
135
5 P
ar
8
Parameter R/W commands
These commands are used to write or read parameters.
Refer to the
AZ
Series OPERATING MANUAL Function Edition for details about parameters. When checking the
AZ
Series OPERATING MANUAL Function Edition, use the parameter name instead of the parameter ID.
8-1
Driver action simulation setting parameter
Parameter ID
Name
Setting range
Initial value
Update
Dec
Hex
511
01FFh
Driver simulation mode
0: Use real motor
1: Virtual motor (when ABZO not connected
=no ABZO information)
2: Virtual motor (when ABZO not connected
=1,800 rev wrap enable)
3: Virtual motor (when ABZO not connected
=900 rev wrap enable)
0
D
8-2
Basic setting parameters
Parameter ID
Name
Setting range
Initial value
Update
Dec
Hex
294
0126h
Base current
0 to 1,000 (1=0.1 %)
1,000
A
296
0128h
Stop current
0 to 1,000 (1=0.1 %)
500
297
0129h
Command filter setting
1: LPF (speed filter)
2: Moving average filter
1
B
298
012Ah
Command filter time constant
0 to 200 ms
1
300
012Ch
Smooth drive function
0: Disable
1: Enable
1
C
301
012Dh
Current control mode
0: Follow the CCM input
1: Alpha control mode (CST)
2: Servo emulation mode (SVE)
0
A
302
012Eh
Servo emulation (SVE) ratio
0 to 1,000 (1=0.1 %)
1,000
303
012Fh
SVE position loop gain
1 to 50
10
304
0130h
SVE speed loop gain
10 to 200
180
305
0131h
SVE speed loop integral time
constant
100 to 2,000 (1=0.1 ms)
1,000
306
0132h
Automatic current cutback function
0: Disable
1: Enable
1
307
0133h
Automatic current cutback
switching time
0 to 1,000 ms
100
308
0134h
Operating current ramp up rate
0 to 100 ms/100 %
0
309
0135h
Operating current ramp down rate
0 to 100 ms/100 %
0
311
0137h
Resonance suppression control
frequency
100 to 2,000 Hz
1,000
312
0138h
Resonance suppression control
gain
−500 to 500
0
313
0139h
Deviation acceleration suppressing
gain
0 to 500
45