Direct data operation
119
4 PR
OFINE
6. Check the operation 1 is completed, and set the following data.
Direct data operation of the operation 2 is started.
•
Output (host controller
→
driver)
Byte
Description
Setting value
Note
8 to 11
Direct data operation position
3,000
3,000 steps
•
To execute direct data operation of the operation 2, set a different value from the operation 1 in
the “position” of the operation 2.
•
If a value other than the “position” is changed, direct data operation of the operation 2 will not be
executed.
3
4
6
5
Write value
Write value
TRIG
Data
DCMD-RDY
TRIG_R
READY
MOVE
Motor operation
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON