Information
166
6 T
Parameter ID
Name
Description
Initial value
Dec
Hex
425
01A9h
Overvoltage information
(INFO-OVOLT)
[AC power input driver]
Sets the generation condition of the overvoltage
information (INFO-OVOLT). [AC power input driver
only]
[Setting range]
120 to 450 V
435
426
01AAh
Undervoltage information
(INFO-UVOLT)
[AC power input driver]
Sets the generation condition of the undervoltage
information (INFO-UVOLT). [AC power input driver
only]
[Setting range]
120 to 280 V
120
427
01ABh
Overvoltage information
(INFO-OVOLT)
[DC power input driver]
Sets the generation condition of the overvoltage
information (INFO-OVOLT). [DC power input driver
only]
[Setting range]
150 to 630 (1=0.1 V)
630
428
01ACh
Undervoltage information
(INFO-UVOLT)
[DC power input driver]
Sets the generation condition of the undervoltage
information (INFO-UVOLT). [DC power input driver
only]
[Setting range]
150 to 630 (1=0.1 V)
180
431
01AFh
Tripmeter information (INFO-TRIP)
Sets the generation condition of the tripmeter
information (INFO-TRIP).
[Setting range]
0: Disable
1 to 2,147,483,647 (1=0.1 kRev)
0
432
01B0h
Odometer information (INFO-ODO)
Sets the generation condition of the odometer
information (INFO-ODO).
[Setting range]
0: Disable
1 to 2,147,483,647 (1=0.1 kRev)
0
433
01B1h
Cumulative load 0 information
(INFO-CULD0)
Sets the generation condition of the cumulative
load 0 information (INFO-CULD0).
[Setting range]
0 to 2,147,483,647
0
434
01B2h
Cumulative load 1 information
(INFO-CULD1)
Sets the generation condition of the cumulative
load 1 information (INFO-CULD1).
[Setting range]
0 to 2,147,483,647
0
435
01B3h
Cumulative load value auto clear
Clears the cumulative load when operation is
started (at the ON edge of the MOVE output).
[Setting range]
0: Disable
1: Enable
1
436
01B4h
Cumulative load value count divisor
Sets the divisor of the cumulative load.
[Setting range]
1 to 32,767
1
444
01BCh
INFO-USRIO output selection
Selects the output signal to be checked in the
INFO-USRIO output.
[Setting range]
Output signal
_
128:
CONST-OFF
445
01BDh
INFO-USRIO output inversion
Sets the output logic of the INFO-USRIO output.
[Setting range]
0: Not invert
1: Invert
0