![Oracle Sun Network QDR InfiniBand Gateway Switch Service Manual Download Page 14](http://html1.mh-extra.com/html/oracle/sun-network-qdr-infiniband-gateway-switch/sun-network-qdr-infiniband-gateway-switch_service-manual_1646262014.webp)
6
Sun Network QDR InfiniBand Gateway Switch Service Manual for Firmware Version 2.1 • March 2013
Related Information
■
“Front Panel LEDs” on page 2
■
“Rear Panel LEDs” on page 3
■
“Check Chassis Status LEDs” on page 4
■
“Check NET MGT Port Status LEDs” on page 4
■
“Check Power Supply Status LEDs” on page 6
■
“Check Fan Status LEDs” on page 7
▼
Check Power Supply Status LEDs
The power supply status LEDs are located on the power supply at the front of the
chassis. See
“Front Panel LEDs” on page 2
.
1. Visually inspect the power supply’s status LEDs.
2. Compare what you see on the power supply to this table.
Caution –
If a power supply has shut down because of a thermal or overcurrent
condition, signified by the amber Attention LED lighting, remove the respective
power cord from the chassis. Allow the power supply to completely cool for at least
15 minutes. A shorter cooling time might cause damage to the power supply when
the power cord is reattached. If the Attention LED lights amber upon reattaching the
power cord, replace the power supply.
3. If the Attention LED is lit, there is a fault with that power supply.
See
“Servicing Power Supplies” on page 41
.
Glyph
Location
Name
Color
State and Meaning
Top
OK
Green
On – 12 VDC is supplied.
Off – No DC voltage is present.
Flashing – No function.
Middle
Attention
Amber
On – Fault detected, 12 VDC shut down.
Off – No faults detected.
Flashing – No function.
Bottom
AC
Green
On – AC power present and good.
Off – AC power not present.
Flashing – No function.