AO SERIES | INSTRUCTIONS MANUAL
31
Command
Description
String (request)
Allowed
input values
Response
(return value)
Set IP Address
Set the static IP Address
of the device
/cgi-bin/set_static_IPaddress:
ADDRESS
ADDRESS
:
- X.X.X.X
(with X
between 0
and 255)
If valid:
ADDRESS
If invalid: -1
Save focusing power
percentage value in
the device memory
Save in the non volatile
memory of the device
the percentage focusing
power value
/cgi-bin/save_position_focus:
POS;FOCUS
POS
:
- Min: 0
- Max: 99
FOCUS (%)
:
-Min:0
- Max: 100
f valid:
FOCUS
If invalid:
-1
Get focusing power
percentage value
from the device
memory
Get from the non volatile
memory of the device
the actual percentage
focusing power value
/cgi-bin/get_position:
POS
POS
:
- Min: 0
- Max: 99
If valid:
FOCUS
If invalid:
-1
Recall focusing power
percentage value
from the device
memory
Get from the non volatile
memory of the device
the actual percentage
focusing power value
and actuate the
piezoelectric
/cgi-bin/recall_position:
POS
POS
:
- Min: 0
- Max: 99
If valid:
FOCUS
If invalid:
-1
If the string is incorrect or doesn’t exists, the
File not found
string is returned.
4.4 Serial communication prototcol
4.4.1 Use
The AOL0223X can be driven with a serial communication protocol: the Hirose 12-pin cable includes
3 pins dedicated to RS232 serial interface. The following table summarizes the connector pinout
and pin functions (for pinout numbering refer to Paragraph 11.1):
Pin number
Pin name
Function
Cable color (for CBGPIO001)
Connect to
7
RS232_GND
Ground reference
Brown
GND
8
RS232_RX
Data receiving pin
White
USER_RS232_TX
9
RS232_TX
Data transmitting pin
Black
USER_RS232_RX
The electrical characteristics of the RS232 transmission protocol have been described in the
“Connection” chapter: please refer to paragraph 11.4 before starting a new connection through
serial interface.