The spindle is designed as Camlock DIN ISO 702-2 no.4 holding fixture.
Fasten workpiece holder
Img.4-11:
Fasten workpiece holder
Turn clamp bolts (1) into the open position.
Clean the taper attachment on the lathe chuck and the spindle fixture.
Fit lathe chuck.
Turn the clamp bolts (1) to the closed position.
CAUTION!
If the reference mark on the clamp bolt is not between the two V markings, the chuck
must be removed and this bolt (D) must be re-adjusted.
Fasten the workpiece holder by turning the clamping bolts clockwise.
The right clamp position is reached when the reference marker at the clamp holder are between
the two marks at the lead spindle seat.
Img.4-12: Marking clamp bolt
1
2
Marking clamp bolt
"open position"
Marking clamp bolt
"closed position"
V
V
V
V