OPTIMUM
M A S C H I N E N - G E R M A N Y
Safety
Version 1.0 dated 2017-03-13
Page 13
Original operating instructions
RD4
GB
R
D
4_
GB
_1.
fm
1.10
Safety check
Check the radial drilling machine before each start-up or at least once per shift. Inform the per-
son responsible immediately of any damage, defects or changes in the operating function.
Check all safety devices
at the beginning of each shift (with the machine stopped),
once a week (with the machine in operation) and
after all maintenance and repair work.
Check that prohibition, warning and information signs and the labels on the radial drilling
machine.
are legible (clean them, if necessary)
are complete (replace if necessary).
INFORMATION
Organise the checks according to the following table;
General check
Equipment
Check
OK
Guards
Mounted, firmly bolted and not damaged
Signs,
Markers
Installed and legible
Date:
Checked by (signature):
Functional check
Equipment
Check
OK
EMERGENCY STOP
push button
After actuating the EMERGENCY STOP push button the
radial drilling machine must be switched off.
Shifting rod with trip
device on the drilling
spindle
After touching the shift rod, the drilling machine must be
switched off. The drilling machine may not start if the shift rod
is actuated.
Clamping lever
Drilling head - cantilever
The spindle may not start if the drill head and cantilever are
not clamped.
Date:
Checked by (signature):