Oiling
Oil column once a day until it is completely filled with
Mobilgear 626 oil.
week
ly
Ba
re stee
l pa
rts
Lubricating
Rub bare steel parts with an acid-free lubricating oil,
e.g. Mobilgear 626 or engine oil.
Coolant tank
Inspection
CAUTION !
The cooling lubricant needs to be checked at
least weekly, including during downtimes,
with regard to its concentration, ph-value,
bacteria and fungal decay.