![background image](http://html1.mh-extra.com/html/omron/ws02-nctc1-e-07-2001/ws02-nctc1-e-07-2001_operation-manual_744249066.webp)
55
Editing Parameter Settings
Section 4-3
For 4-axis NC Units, if the same axis is clicked for the
To
axis as the one
already selected for the
From
axis, the next
To
axis will be selected auto-
matically (in the order
Y
,
Z
,
U
,
X
).
More than one axis can be selected for the
To
axis (except for the axis al-
ready selected as the
From
axis).
For 2-axis NC Units, selecting the Y axis as the
From
axis will automatically
make the X axis the
To
axis, and vice-versa.
3.
Change the
To
axis by clicking on and selecting a different axis.
4.
Verify the
From
and
To
axes, and click the
OK
Button.
4-3
Editing Parameter Settings
4-3-1
Parameter Setting Editing Screen
Select
Parameters
on the project tree, and either double-click or press the
Enter
Key.
Example: The following will be displayed as the 4-axis NC Unit parameter Set-
ting Editing Screen.
4-3-2
Editing Parameter Settings
Select a setting or enter settings directly. Refer to
4-2-2 Editing Settings
for
editing methods.
To Enter Settings
Selecting Settings From
the Drop-down List
1,2,3...
1.
On the Setting Editing Screen, select the setting to be set, and either click
the drop-down list arrow or press the
Space
Bar.
2.
Select an item from the expanded drop-down list either by clicking on it di-
rectly, or by using the Up or Down Keys or entering its list number (
0
,
1
,
2
etc.).
3.
Press the
Enter
Key to collapse the list and set the settings.
Entering Settings Using
the List Numbers
1,2,3...
1.
In the Setting Editing Screen, enter directly the setting to be set.
2.
Press the
Enter
Key or use the Up or Down Keys to set the setting.