![background image](http://html1.mh-extra.com/html/omron/ws02-nctc1-e-07-2001/ws02-nctc1-e-07-2001_operation-manual_744249068.webp)
57
Editing Sequence Settings
Section 4-4
No particular axis is allocated to Tables 1 to 4, but between tables the same
axis cannot be specified in the same sequence.
Example: The following screen will be displayed after setting sequence Num-
bers 0 to 3 in Table 1 for a 4-axis NC Unit.
To Clear to Default
Settings
Use the following procedure to clear specific settings to their default values.
(Refer to
4-2-4 Clearing Settings
for details.)
1,2,3...
1.
On the Sequence Setting Editing Screen, select the settings to be cleared
to the default values, or designate the range by clicking and dragging.
2.
Select
Edit/Clear
To Copy Axes
For 2-axis and 4-axis NC Units, data can be copied from one axis to another
axis by selecting the source and destination axes. (Refer to
4-2-5 Copying
Axis Settings
for details.)
1,2,3...
1.
Select
Edit/Copy Axis
.
2.
Under
From
and
To
, select the axes to be copied from and to respectively.
3.
Click the OK Button.
Position designa-
tion
0 (absolute position) or 1 (relative position)
End code
00 to 06 Hex (0 to 6)
0 = terminating; 1 = automatic; 2 = continuous; 3 = bank end; 4
= speed control; 5 = interrupt feeding (forward direction); 6 =
interrupt feeding (reverse direction)
Dwell #
00 to 13 Hex (0 to 19) (no dwell time for 0)
Accel. #
0 to 9 Hex (0 to 9) (0 = Acceleration time in parameter settings)
Decel. #
0 to 9 Hex (0 to 9) (0 = Deceleration time in parameter settings)
Start speed
00 to 63 Hex (0 to 99)
Target speed
00 to 63 Hex (0 to 99)
Item
Setting range