![background image](http://html1.mh-extra.com/html/omron/v720-series/v720-series_operation-manual_1633447045.webp)
Mounting
Section 4-3
4-9
4-3
Mounting
The Controller can be mounted to DIN tracks or enclosed-mounted to panels
with screws.
Enclosed Mounting
Be sure to secure the Controller with M4 screws together with spring
washers and flat washers. Do not use an organic screw adhesive on the
screws to fix them in place, as this may cause the Controller case to crack.
DIN Track Mounting
TTwo, M4
DIN track (1m long)
OMRON PFP-100N2 is
recommended.
PFP-100N2 DIN Track
PFP-M End Plate
Height: 80 mm max.
End plate
Mounting hook
Take the height of the DIN track into
consideration at the time of mounting.
Note
(1)
Hook the Controller to part A. Then press
the Controller in direction B to mount the
Controller
(2)
Pull the mounting hook downwards, then lift
the Controller upwards to disconnect the
Controller.
(See note)
Closed mounting
DIN track
V720-CD1D
V720-CD1D