![Omron V720 Series Operation Manual Download Page 112](http://html1.mh-extra.com/html/omron/v720-series/v720-series_operation-manual_1633447112.webp)
Troubleshooting
Section 6-5
6-7
6-5
Troubleshooting
Main Check Flowchart
If an error results, fully check the whole situation, determine the relationship
between the system and any other device, and refer to the following
flowcharts for troubleshooting.
Use the following main check flowchart to determine the cause of the error.
Main check flowchart
Are all devices in the system
connected properly?
Are host
communications
normal?
Go to the system connections
check flowchart on page 6-6
Go to the host communications
check flowchart on page 6-7
Go to the communications
check flowchart on page 6-8
Go to operating environment
check flowchart on page 6-9
Are communications
between the Controller and
Tag normal?
Is the operating
environment normal?
Replace the Controller
Normal
No
No
No
No
Normal
Normal
Normal