Switch Settings
Section 4-1
4-3
4-1-2
Settings
Use the provided screwdriver to make switch settings as shown below.
4-1-3
Default Set Values
The following table shows default set values.
Name
Default set
value
Meaning
SW1
Node number
0
Node number 0
SW2
RESERVED
0
Not used
SW3-1
Tag Communication speed
OFF
Standard mode
SW3-2
RESERVED
OFF
Not used
SW3-3
Offline Read Test mode setting
OFF
Normal mode
SW3-4
OFF
SW3-5
OFF
SW3-6
OFF
SW3-7
RESERVED
OFF
Not used
SW3-8
BCC setting
OFF
BCC enable
SW4-1
OFF
SW4-2
Baud rate setting
OFF
38,400 bps
SW4-3
Data length setting
OFF
7 (ASCII7)
SW4-4
OFF
SW4-5
Parity bit setting
OFF
Even
SW4-6
Stop bit length setting
OFF
2
SW4-7
Communications mode setting
OFF
No ACK/NACK control
SW4-8
Time-out setting
OFF
See note. (500 ms)
Note The pin 8 setting of SW4 will be meaningless if pin 7 is set to OFF.
SW3 (left)
SW4 (right)