![Omron V720 Series Operation Manual Download Page 70](http://html1.mh-extra.com/html/omron/v720-series/v720-series_operation-manual_1633447070.webp)
Communications Commands and Responses
Section 5-3
5-12
2)
Read (RD)
Command for the use of designating a specific Tag and reading data after detection.
Command Frame Structure
STX
Node No.
Command
code
“RD”
Commu-
nications
Data
type
Fixed
“0”
First read
page
No. of read
pages
ETX BCC
1
2
2
2
1
1
2
2
1
1
Communications
Specifies the temporary Tag No. to be read in HEX.
□□
: Temporary No.
(For
□□
, the values from “00” to “7F” are available.)
For details, refer to 5-5 Communications Methods.
Data type
Specifies whether the read data is represented in ASCII or HEX.
A: ASCII code
H: HEX code
For details, refer to 5-6 Data Type.
First read page
Specifies the first page of the Tag containing data to be read in HEX.
Setting range: 00h to 0Ah, FFh
(FFh can be specified only when using Philips’ block 4 as user memory. For details,
refer to 2-5 Tag Memory Map.)
No. of read pages
Specifies the number of pages to which data is written in HEX.
Setting range: 01h to 0Ch
Response Frame Structure
STX
Node No.
Retry
flag
Command
code
“RD”
Response
code
“00”
Temporary
No.
Read data
ETX BCC
1
2
1
2
2
2
Specified
number
1
1
Response code
00: Normal completion
For other response codes, refer to 5-10 Response Code List.
Read data
Indicates the data having been read. The number of characters of the data is as
follows:
ASCII code: No. of read pages x 4
HEX code: No. of read pages x 8
Temporary No.
As a normal response, the values 00 to 7F are returned.