![Omron V720 Series Operation Manual Download Page 82](http://html1.mh-extra.com/html/omron/v720-series/v720-series_operation-manual_1633447082.webp)
Communications Commands and Responses
Section 5-3
5-24
9)
Setting of Quiet Bit (QB)
The QB Command is used to set the Quiet Bit. If this bit is enabled, no responses are returned
for commands (except the EAS Check Command).
Command Frame Structure
STX
Node No. Command
code
“QB”
Setting
ETX BCC
1
2
2
2
1
1
Setting
Setting range: 00h to 01h
00h: Quiet Bit disabled
01h: Quiet Bit enabled
Response Frame Structure
STX
Node No. Retry
Flag
Command
code
“QB”
Response
code
“
00
”
ETX BCC
1
2
1
2
2
1
1
Response code
00 : Normal completion
For other response codes, refer to 5-10 Response Code List.
Note 1
If BCC is disabled (i.e., pin 8 on DIP switch 3 is set to ON), BCC is not attached to either
command or response frames.
Note 2
This function can be used with Controller software versions 1.5 or later. The software ver-
sion can be read with the Version Command (VS).
10)
Version (VS)
The VS Command is used to read the Controller software version.
Command Frame Structure
STX
Node No. Command
code
“VS”
ETX BCC
1
2
2
1
1
Response Frame Structure
STX
Node No. Retry
Flag
Command
code
“ES”
Response
code
“
00
”
Software version
ETX BCC
1
2
1
2
2
4
1
1
Response code
00 : Normal completion
For other response codes, refer to 5-10 Response Code List.
Note If BCC is disabled (i.e., pin 8 on DIP switch 3 is set to ON), BCC is not at-