4-3
Section
Installing Data Carriers
54
V600-D23P66 Data Carriers
Attach the Holder using M3 plain-head screws and washers. The tightening
torque is 0.3 to 0.5 N
m.
The Data Carriers can be installed in any direction with respect to movement rel-
ative to the Sensor.
Two, M3
The transmission distance will be reduced if there is metal in back of a Data Car-
rier. When mounting on a metal surface, use the special Attachment (sold sepa-
rately) or insert a non-metallic spacer (e.g., plastic, wood, etc.). The following
diagrams show the relationship between the distance between a Data Carrier
and a metal surface and the transmission distance. The Attachment is 10 mm
thick.
Installation on an
Attachment
V600-D23P66
Distance to metal (X)
Metal casing
Sensor
Data Carrier
Metal
Trans-
mission
distance
Trans-
mission
distance
(100% =
non-me-
tallic sur-
face) (Y)
M3 plain-head
screw
V600-HS63
V600-HS67
Align the Attachment and Data Carrier so that the mounting holes align.
Install the Sensors and Data Carriers so that they are as parallel as possible to
each other. Communications will be possible even if they are not perfectly paral-
lel, but he transmission distance will be affected, as listed in the following tables.
Sensor
V600-D23P66
Data Carrier
Metal
casing
Installation Method
Effects of Metal
Effect of Misalignment