4-2
Section
Installing Sensors
44
4-1-4 Connecting Sensors
Hold the black part A of the connector, align the notch on the connector with the
notch in the jack, and insert the connector until it snaps in.
To disconnect the Sensor, pull portion B of the connector.
Note
1. When inserting the connector, always hold the molded section A. Pressing
part B will not lock the connector.
2. When disconnecting the connector, always hold part B and then pull it out.
Amplifier
Part B
Part A
4-2
Installing Sensors
4-2-1 Installation Method
V600-HS51
The V600-HS51 Sensor is M12 in size. When embedding or attaching to metal,
separate the communications section (coil tip) from the metal by at least 15 mm
in all directions.
30 (
±
15)-mm dia. min.
7 mm min.
Sensor
Surrounding metal
Note Do not let the surrounding metal extend beyond the end of the Sensor.
Mounting to Brackets: Mounting Hole Dimensions
12
+0.5
0
mm dia.